meq per 100 g paste. An assumption, not a measurement (Low); Route A replaces it with a titration.
Electrode
°C
After calibrating on 7.00 and 4.01, read 4.01 again as an unknown.
Paste pH, corrected from the slurry
Paste pH, estimate
–
ideal to activity-corrected
Shift applied
–
paste minus slurry
Route
–
TA of the paste
–
meq / 100 g
Ionic strength, paste
–
mol/L, estimate
Indicative reading at 20 °C
–
−0.002 per °C, Low
Electrode check
Slope
–
mV per pH
Efficiency
–
% of Nernst
Offset at pH 7
–
mV
Sample recipe
–
For the base-dose planner
–
The link opens the base-dose planner with these as the native pH and TA of the first ingredient (set its mass there). The corrected paste pH is the "measure cold" value the two-pass base procedure refers to.
A measurement aid. The corrected value is an estimate; log the measured slurry value alongside it. Colorimetric strips cannot be read against a dark paste, and a diluted slurry is still coloured, so there is no strip mode.